Welbilt Multiplex ND21RS00 Nitrogen Beverage Dispenser
Welbilt Multiplex ND21RS00 Nitrogen Beverage Dispenser
Regular price
$2,000.00 USD
Regular price
$4,999.95 USD
Sale price
$2,000.00 USD
Unit price
/
per
Low stock: 1 left
This item was working when removed from building
Shipping/Return Information at bottom - Click Here -
Does not include nitrogen, kegs, or anything other than what is pictured
Some information we found online
Max Capacity: 3 - 3 Gallon (11.36L) Coffee Kegs
Volume: 5.7Ft3 (161L)
Weight: 168lbs (76kg)
BTU/hr: 1430 (0.42 kW)
Refrigerant Charge: R404A - 7.0 oz (198g)
Voltage: 115, 60Hz, Single Phase
Total Amps: 6.0 A
Breaker Size (Max): 15 A
HP: 1/5
- Allows the user to nitrogenate a beverage at the point of dispense
- Infuses all types of beverages including coffees, teas, juices, and cocktails.
- Pours both still and nitrogenated beverages from a common source.
- Creates a true “Theatre of the Pour” with a thick, frothy head and waterfall effect similar to a dark, stout beer.
Important
- Use only food grade nitrogen (99.5% pure).
- ALWAYS connect the nitrogen cylinder to the primary regulator and NEVER directly to the unit, keg, or dispensing system. Failure to do so could result in an explosion with possible death or injury when the cylinder valve is opened.
- ALWAYS follow correct procedures when cylinders are changed.
- ALWAYS secure the cylinder in an upright position with a chain.
- NEVER drop or throw a nitrogen cylinder.
- ALWAYS keep a nitrogen cylinder away from heat. Store extra cylinders in a cool place (preferably 70°F). Securely fasten with a chain in an upright position when storing.
- Units are intended for indoor use only.
- The location MUST be level both front to back and side to side, stable and capable of supporting the weight of the equipment.
- Position the equipment so it will not tip or slide.
- Recommended air temperature is 41° - 86°F (5° - 30°C), and must not exceed 90°F (32°C), climate class 4.
- Location must have proper ventilation, DO NOT install in an enclosure/enclosed cabinet with no access to ambient air.
- The location must not be near heat-generating equipment or in direct sunlight and must be protected from weather.
- Verify floor of install location is within 1/2" (1.3 cm) of level front to back, side to side.
- Keep equipment area clear of combustible material.
- Do not install the equipment directly over a drain. Steam rising up out of the drain will adversely affect operation, air circulation, and damage electrical /electronic components
- Do not install in an area where a high-pressure water jet could be used for cleaning.